Read more
Minimum Order Quantity | 1 Piece |
Type | Orthopedic External Fixator |
Usage/Application | Orthopedic Surgery |
Material | Stainless Steel |
Brand | JMS |
Design | Standard |
Color | Bright |
CE Marking | With CE Marking |
Wire Fixation Bolt - Slotted External Fixator Ring Type device is a specialized form of external fixator, a circular fixator, modular in construction. Stainless steel / Carbon Fiber rings are fixed to the bone via stainless heavy-gauge wire (called "pins" or Kirschner wires). The rings are connected to each other with threaded rods attached through adjustable nuts. Jindal Medi Surge are pioneer in OEM & Brand manufacturing of the said devices, available in Stainless Steel, Carbon Fiber & Titanium Alloy
Minimum Order Quantity | 1 Piece |
Type | Orthopaedic Implants |
Usage/Application | Bone Fixation |
Material | Steel |
Brand | JMS |
Thickness | Standard |
Application | Orthopedic Trauma Surgery |
LONG CONNECTION PLATE WITH THREADED END | |
4245.005 | 5 Holes |
4245.006 | 6 holes |
4245.007 | 7 Holes |
4245.008 | 8 holes |
4245.009 | 9 Holes |
4245.010 | 10 Holes |
4245.011 | 11 Holes |
4245.012 | 12 Holes |
4245.013 | 13 Holes |
4245.014 | 14 Holes |
4245.015 | 15 Holes |
Minimum Order Quantity | 1 Piece |
Material | Stainless Steel |
Brand | Jindal Medi Surge |
Color | Bright |
CE Marking | With CE Marking |
Finishing | Bright Finish |
Usage/Application | Orthopedic Surgery |
Minimum Order Quantity | 1 Piece |
Material | Stainless Steel |
Brand | Jindal Medi Surge |
Color | Bright |
Type | Orthopedic External Fixator |
Usage/Application | Orthopedic Surgery |
Design | Standard |
Size | 40mm to 450mm Length |
Material | Stainless Steel & Titanium |
Brand | JMS |
Color | Bright Finish |
Type | Orthopedic External Fixator |
Usage/Application | Orthopedic Surgery |
Design | Standard |
CE Marking | With CE Marking |
Minimum Order Quantity | 1 Piece |
Usage/Application | Orthopedic Surgery |
Brand | JMS |
Type | Orthopedic |
Color | Bright Finish |
Material | Titanium |
Properties | ORTHOPEDIC IMPLANT |
LOCKING DISTAL HUMERUS PLATE DHLP MEDIA SIDE 2.7/3.5MM ORTHOPEDIC IMPLANT With locked plating, the use of locking screws provides locking compression, which is especially useful in fractures prone to collapse. The locking humeral plate was designed for humeral fractures whereby it is contoured to the anatomy of the lateral aspect of the proximal humeral metaphysis and proximal diaphysis. Fragments must be reduced before locking screws are placed. The plate may be used to aid reduction and non-locked screws may be used to achieve interfragmentary compression. All Jindal Medi Surge Orthopedic Locking Humerus Bone Plates are made from medical grade stainless steel & titanium only.
Minimum Order Quantity | 1 Piece |
Material | Stainless Steel |
Brand | Jindal Medi Surge |
Type | Implantation Equipment |
Finishing | Bright Finish |
Usage/Application | Orthopedic Surgery |
Is It ISO Certified | ISO Certified |
Minimum Order Quantity | 1 Piece |
Material | Stainless Steel |
Brand | JMS |
Color | Bright Finish |
Type | Orthopedic Implant |
Usage/Application | Orthopedic Surgery |
Design | Standard |
CE Marking | With CE Marking |
Minimum Order Quantity | 1 Piece |
Material | Stainless Steel |
Brand | JMS |
Type | Orthopedic External Fixator |
Usage/Application | Orthopedic Surgery |
Design | Standard |
Finishing | Bright Finish |
Country of Origin | Made in India |
Multipin Fixation Clamp External Fixator Ring Type device is a specialized form of external fixator, a circular fixator, modular in construction. Stainless steel / Carbon Fiber rings are fixed to the bone via stainless heavy-gauge wire (called "pins" or Kirschner wires). The rings are connected to each other with threaded rods attached through adjustable nuts. Jindal Medi Surge are pioneer in OEM & Brand manufacturing of the said devices, available in Stainless Steel, Carbon Fiber & Titanium Alloy
Minimum Order Quantity | 1 Piece |
Type | Orthopedic External Fixator |
Usage/Application | Orthopedic Surgery |
Size | 20mm to 60mm |
Material | Stainless Steel |
Brand | JMS |
Design | Standard |
Threaded Socket External Fixator Ring Type device is a specialized form of external fixator, a circular fixator, modular in construction. Stainless steel / Carbon Fiber rings are fixed to the bone via stainless heavy-gauge wire (called "pins" or Kirschner wires). The rings are connected to each other with threaded rods attached through adjustable nuts. Jindal Medi Surge are pioneer in OEM & Brand manufacturing of the said devices, available in Stainless Steel, Carbon Fiber & Titanium Alloy
Minimum Order Quantity | 1 Piece |
Type | Orthopedic External Fixator |
Usage/Application | Orthopedic Surgery |
Material | Stainless Steel |
Brand | JMS |
Design | Standard |
Color | Bright |
Number Of Holes | 1 to 5 |
Post Male / Female External Fixator Ring Type device is a specialized form of external fixator, a circular fixator, modular in construction. Stainless steel / Carbon Fiber rings are fixed to the bone via stainless heavy-gauge wire (called "pins" or Kirschner wires). The rings are connected to each other with threaded rods attached through adjustable nuts. Jindal Medi Surge are pioneer in OEM & Brand manufacturing of the said devices, available in Stainless Steel, Carbon Fiber & Titanium Alloy
Minimum Order Quantity | 1 Piece |
Material | Stainless Steel |
Brand | JMS |
Type | Orthopedic Implant |
Usage/Application | Orthopedic Surgery |
Design | Standard |
Color | Right Finish |
CE Marking | With CE Marking |
DCP PLATE DCP HOLE 90° ORTHOPEDIC IMPLANT The Intended Use of Jindal Medi Surge's Angled Blade Plates is for temporary fixation, correction or stabilization of bones in the proximal and/ or distal femur. Indications- 130° Angled Blade Plate Fractures and revisions of the proximal third of the femur in skeletal mature patients. Condylar Plates, 95° Fractures and revisions of the proximal and distal third of the femur in skeletal mature patients. Precaution: Use of the Condylar Plate on the proximal femur requires either an intact cal-car of the femur or that a stable continuous medial contact is reestablished. Osteotomy Plates 90°/100°/110°/120°/130° Hip Plate Osteotomies on the proximal femur in skeletal mature patients. Note: Before the surgery, all components of the deformation must be recognized and the angles of correction must be defined. Precaution: The preset angles have to be followed exactly during the intervention. All Plates are made from Medical Grade Stainless Steel & Titanium.
Size | 90 Degree |
Material | Stainless Steel |
Brand | JMS |
Color | Bright Finish |
Type | Orthopedic External Fixator |
Usage/Application | Orthopedic Surgery |
Design | Standard |
Minimum Order Quantity | 1 Piece |
Model Name/Number | JMS-075 |
Material | Titanium |
Brand | JMS |
Type | Implantation Equipment |
Usage/Application | Orthopedic Surgery |
Size | Standard |
Design | Standard |
Brand | JMS |
Material | Stainless Steel |
Thickness | Standard |
Type | Orthopedic External Fixator |
Shape | Stainless Steel |
CE Marking | With CE Marking |
Usage/Application | Orthopedic Surgery |
Minimum Order Quantity | 1 Piece |
Material | Stainless Steel |
Brand | JMS |
Size | 6 to 10 Inch |
Type | Veterinary clamp |
Color | Bright |
CE Marking | With CE Marking |
Minimum Order Quantity | 1 Piece |
Usage/Application | Orthopedic Surgery |
Brand | JMS |
Type | Orthopedic IMPLANT |
Color | Bright Finish |
Material | TITANIUM |
No. Of Holes | 3 to 9 |
Number Of Holes | 3 to 9 |
LOCKING T PLATE ORTHOPEDIC IMPLANT The aim of any surgical fracture treatment is to reconstruct the anatomy and restore its function. Internal fixation is distinguished by precise reduction, stable fixation preservation of blood supply, and early functional mobilization. Locking Plate and screw osteosynthesis have been established and clinically recognized for quite some time. Clinical results have been improved by using (internal fixation) in metaphyseal fractures and in osteopenic bone. Jindal Medi Surge Orthopedic Small Fragment Locking compression plate system is part of medical grade stainless steel and titanium plate and screw system that merges locking head screw technology with conventional plating techniques. The Small Locking Compression Plate System has many similarities to existing non-locking plate systems but with a few important improvements. Instead of cortical screws, locking head screws provide the ability to create a fixed-angle construct which also provides advantages in osteopenic bone or multifragmentary fractures where traditional screw purchase is compromised. Locking head screws does not rely on plate/bone compression to maintain stability, but function similarly to multiple small angled blade plates. The Small Locking Compression Plate System has the following features: Uniform hole spacing, Load (compression) and neutral screw positions, Small Locking Compression Plates have combination locking and compression holes (combi holes), The combi holes allow placement of standard cortical and cancellous bone screws on one side or threaded conical locking screws on the opposite side of each hole. Threaded hole section for locking screw. Dynamic compression unit hole section for standard screw. Locking screw in the threaded side of the plate hole. Indications: All Small Fragment LCP Locking Compression Plates are intended for fixation of fractures, osteotomies, and non-union of the clavicle, scapula, olecranon, humerus, radius, ulna, pelvis, distal tibia and fibula, particularly in osteopenic bone. Fixation Principles: The following points distinguish treatment using locking head screw technology from conventional plating techniques: It enables fracture treatment using compression plating with conventional cortical or cancellous screws. A locking compression plate can be used as an internal fixator and permit stable bridging over shattered zones. The small locking compression plate system permits the combination of conventional and locking screws. Unicortical locking screw permits better vascularity.
Minimum Order Quantity | 1 Piece |
Usage/Application | Orthopedic Surgery |
Brand | JMS |
Type | Orthopedic IMPLANT |
Color | TITANIUM |
Material | TITANIUM |
No. Of Holes | 3 to 8 |
Number Of Holes | 3 to 8 |
LOCKING SUPERIOR ANTERIOR CLAVICLE PLATE 2.7/3.5MM ORTHOPEDIC IMPLANT The aim of any surgical fracture treatment is to reconstruct the anatomy and restore its function. Internal fixation is distinguished by precise reduction, stable fixation preservation of blood supply, and early functional mobilization. Locking Plate and screw osteosynthesis have been established and clinically recognized for quite some time. Clinical results have been improved by using (internal fixation) in metaphyseal fractures and in osteopenic bone. Jindal Medi Surge Orthopedic Small Fragment Locking compression plate system is part of medical grade stainless steel and titanium plate and screw system that merges locking head screw technology with conventional plating techniques. The Small Locking Compression Plate System has many similarities to existing non-locking plate systems but with a few important improvements. Instead of cortical screws, locking head screws provide the ability to create a fixed-angle construct which also provides advantages in osteopenic bone or multifragmentary fractures where traditional screw purchase is compromised. Locking head screws does not rely on plate/bone compression to maintain stability, but function similarly to multiple small angled blade plates. The Small Locking Compression Plate System has the following features: Uniform hole spacing, Load (compression) and neutral screw positions, Small Locking Compression Plates have combination locking and compression holes (combi holes), The combi holes allow placement of standard cortical and cancellous bone screws on one side or threaded conical locking screws on the opposite side of each hole. Threaded hole section for locking screw. Dynamic compression unit hole section for standard screw. Locking screw in the threaded side of the plate hole. Indications: All Small Fragment LCP Locking Compression Plates are intended for fixation of fractures, osteotomies, and non-union of the clavicle, scapula, olecranon, humerus, radius, ulna, pelvis, distal tibia and fibula, particularly in osteopenic bone. Fixation Principles: The following points distinguish treatment using locking head screw technology from conventional plating techniques: It enables fracture treatment using compression plating with conventional cortical or cancellous screws. A locking compression plate can be used as an internal fixator and permit stable bridging over shattered zones. The small locking compression plate system permits the combination of conventional and locking screws. Unicortical locking screw permits better vascularity.
Minimum Order Quantity | 1 Piece |
Type | Orthopedic External Fixator |
Usage/Application | Orthopedic Surgery |
Material | Stainless Steel |
Brand | JMS |
Design | Standard |
CE Marking | With CE Marking |
Feature | Reusable |
Hinge Joint External Fixator Ring Type device is a specialized form of external fixator, a circular fixator, modular in construction. Stainless steel / Carbon Fiber rings are fixed to the bone via stainless heavy-gauge wire (called "pins" or Kirschner wires). The rings are connected to each other with threaded rods attached through adjustable nuts. Jindal Medi Surge are pioneer in OEM & Brand manufacturing of the said devices, available in Stainless Steel, Carbon Fiber & Titanium Alloy
Minimum Order Quantity | 1 Piece |
Brand | JMS |
Material | Stainless Steel |
Type | Orthopaedic Implants |
Usage/Application | Orthopedic External Fixator |
Product Type | Orthopedic External Fixator |
Finishing | Bright Finish |
Country of Origin | Made in India |
Nylon Insert Nut External Fixator Ring Type device is a specialized form of external fixator, a circular fixator, modular in construction. Stainless steel / Carbon Fiber rings are fixed to the bone via stainless heavy-gauge wire (called "pins" or Kirschner wires). The rings are connected to each other with threaded rods attached through adjustable nuts. Jindal Medi Surge are pioneer in OEM & Brand manufacturing of the said devices, available in Stainless Steel, Carbon Fiber & Titanium Alloy
Minimum Order Quantity | 1 Piece |
Material | Stainless Steel |
Brand | JMS |
Color | Bright Finish |
Type | Implantation Equipment |
Finishing | Bright Finish |
Usage/Application | Orthopedic Surgery |
Is It ISO Certified | ISO Certified |
4.0MM LOCKING HEAD FULL THREAD SELF TAPPING ORTHOPEDIC IMPLANT Jindal Medi Surge [JMS] Orthopedic Small Fragment Locking Screw Implant: are similar to Standard Plates that have numeral-8 Combi holes, on one side the hole is threaded, so that it can accommodate locking screws. Use of these plates depend upon the fracture situation. locking plates can be used as Compression plates, Locked fixations or as Standard implants as the need may be. locking feature provides angular stability. All implants are made from medical grade stainless steel & titanium alloy.
Type | Implantation Equipment |
Brand | JINDAL MEDI SURGE |
Material | S.S.304 |
Usage/Application | ORTHOPAEDIC SURGERY |
Application | ORTHOPEDIC |
Condition | New |
USE | Orthopedic External Fixator Trauma Surgery |
JCTEV-S | Ctev External Fixator Set (Small) |
Link Joints, Small | |
Connecting Rod, Dia : 2.5 mm, Length : 100 mm | |
Connecting Rod, Dia : 2.5 mm, Length : 150 mm | |
Connecting Rod, Dia : 2.5 mm, Length : 200 mm | |
L' Rod, Dia : 2.5 mm | |
Z' Rod, Dia : 2.5 mm | |
Distractor, Double Hole, Length : 100 mm | |
Distractor, Double Hole, Length : 150 mm | |
K. Wire, Dia : 1.5 mm X 150 mm | |
K. Wire, Dia : 2.0 mm X 150 mm | |
Foot Plate | |
Allen Key 2.5mm | |
JCTEV-M | Ctev External Fixator Set (Medium) |
Link Joints, Medium | |
Connecting Rod, Dia : 3.0 mm, Length : 125 mm | |
Connecting Rod, Dia : 3.0 mm, Length : 150 mm | |
Connecting Rod, Dia : 3.0 mm, Length : 200 mm | |
L' Rod, Dia : 3.0 mm | |
Z' Rod, Dia : 3.0 mm | |
Distractor, Double Hole, Length : 150 mm | |
Distractor, Double Hole, Length : 200 mm | |
K. Wire, Dia : 2.0 mm X 150 mm | |
K. Wire, Dia : 2.5 mm X 150 mm | |
Foot Plate | |
Allen Key 3.0mm | |
JCTEV-L | Ctev External Fixator Set (Large) |
Link Joints, Large | |
Connecting Rod, Dia : 4.0 mm X 125 mm | |
Connecting Rod, Dia : 4.0 mm X 150 mm | |
Connecting Rod, Dia : 4.0 mm X 200 mm | |
L' Rod, Dia : 4.0 mm | |
Z' Rod, Dia : 4.0 mm | |
Distractor, Double Hole, Length : 150 mm | |
Distractor, Double Hole, Length : 250 mm | |
K. Wire, Dia : 2.5 mm X 150 mm | |
Foot Plate | |
Allen Key 3.0mm |
Usage/Application | Orthopedic Surgery |
Material | Carbon Fiber |
Brand | Jindal Medi Surge |
Packaging Type | Standatd |
Color | Black |
I Deal In | New Only |
Minimum Order Quantity | 1 Piece |
Size | 40mm To 450mm |
Material | Stainless Steel |
Brand | JMS |
Color | Bright |
Type | Orthopedic External Fixator |
Usage/Application | Orthopedic Surgery |
Design | Standard |
CE Marking | With CE Marking |
Usage/Application | Orthopedic Surgery |
Material | Carbon Fiber |
Brand | Jindal Medi Surge |
Shape | Straight |
Packaging Type | Standard |
Color | Black |
I Deal In | New Only |
Minimum Order Quantity | 1 Piece |
Material | Stainless Steel |
Number of Holes | 17 Holes |
Model Name/Number | 5131S.110 |
Size | As per customer requirement |
Band | JMS |
Model Name/ Number | 5131S.110 |
Sterile/ Non Sterile | Non Sterile |
Usage/Application | Hospital |
Packaging Type | Pack |
Country of Origin | Made in India |
Minimum Order Quantity | 1 Piece |
Model Name/Number | 510.013 |
Size | 4.0mm Full Thread |
Thickness | Locking Screw |
Cancellous Locking Head Screw | 4.0mm |
Drill Bit for Shaft | Locking |
Adjustable Seat Height | Full Thread |
Use Drills Diameter | 4.0mm |
Step Drill Bit | Full Thread |
Cannulated Screw thread | Full Thread |
Country of Origin | Made in India |
Minimum Order Quantity | 1 Piece |
Material | Stainless Steel |
Sterile/ Non Sterile | Non Sterile |
Size | 3.5MM/4.0MM |
Disposable/ Reusable | Reusable |
Brand | JINDAL MEDI SURGE |
Model Name/Number | 577.004 |
Color | Silver |
Packaging Type | Pack |
Usage/Application | Hospital |
Country of Origin | Made in India |
Minimum Order Quantity | 1 Piece |
Material | Titanium |
Sterile/ Non Sterile | Non Sterile |
Size | 3.5MM |
Disposable/ Reusable | Reusable |
Brand | JINDAL MEDI SURGE |
Model Name/Number | 531T.003 |
Usage/Application | Hospital |
Country of Origin | Made in India |
Minimum Order Quantity | 1 Piece |
Material | Titanium |
Sterile/ Non Sterile | Non Sterile |
Size | 3.5/4.0MM |
Disposable/ Reusable | Reusable |
Brand | JINDAL MEDI SURGE |
Model Name/Number | 577T.004 |
Usage/Application | Hospital |
Country of Origin | Made in India |
Minimum Order Quantity | 1 Piece |
Material | Titanium |
Size | 3.5/4.0MM |
Sterile/ Non Sterile | Non Sterile |
Disposable/ Reusable | Reusable |
Brand | JINDAL MEDI SURGE |
Model Name/Number | 550T.002 |
Usage/Application | Hospital |
Country of Origin | Made in India |
Minimum Order Quantity | 1 Piece |
Brand | JMS |
Type | Clamps |
Usage/Application | Ilizarov |
Material | SS304 |
Shape | Round |
CE Marking | With CE Marking |
Feature | Reusable |
Material | Carbon Fiber |
Brand | Jindal Medi Surge |
Color | Black |
Packaging Type | Standard |
Usage/Application | Orthopedic Surgery |
I Deal In | New Only |
Minimum Order Quantity | 1 Piece |
Color | SILVER |
Material | Aluminium |
Brand | JINDAL MEDI SURGE |
Size/Capacity | As per customer requirement |
Usage/Application | As per customer requirement |
Country of Origin | Made in India |