Orthopedic Plates

Prominent & Leading Manufacturer from New Delhi, we offer locking distal lateral fibula plate 2.7/3.5mm left/right ss 316l, locking distal tibia medial plate with tab 3.5mm right/left ss 316l, locking posterior medial tibia plate 3.5mm ss 316l, locking clavicle hook plate 3.5mm and medial anterior clavical locking plate variable angle left/right titanium.

Locking Distal Lateral Fibula Plate 2.7/3.5mm Left/Right SS 316L

Request Callback

₹ 875 / Piece Get Latest Price

Product Brochure
MaterialStainless Steel
Sterile/ Non SterileNon Sterile
Disposable/ ReusableDisposable
BrandJINDAL MEDI SURGE
Model Name/Number589.003
ColorSilver
Packaging TypePack
Usage/ApplicationHospital
Country of OriginMade in India
The Orthopedic Locking Distal Lateral Fibula Plate 2.7/3.5mm Left/Right SS316L is an implant specifically designed for the fixation of fractures and deformities in the distal lateral fibula. It provides stable and rigid fixation, ensuring proper alignment during healing, especially in complex fractures, osteoporotic bones, or cases where conventional plates may not provide sufficient support. Here's a comprehensive breakdown of its features, applications, and advantages:
1. Locking Plate Design:The locking mechanism involves screws that lock into the plate, forming a fixed-angle construct. This provides stability even in weak or osteoporotic bone, minimizing the risk of screw loosening or migration.Locking screws are used for optimal fixation and stability, allowing the bone fragments to heal in the correct position.2. Distal Lateral Fibula Plate:The plate is specifically designed to address fractures located in the distal lateral fibula, which is the smaller bone on the outer side of the lower leg, near the ankle.It is particularly useful in managing lateral malleolar fractures, fractures near the syndesmosis, and those extending into the ankle joint.The lateral position ensures that the plate does not interfere with important soft tissues and anatomical structures like tendons.3. 2.7mm and 3.5mm Screw Compatibility:This plate accommodates both 2.7mm and 3.5mm locking screws, offering versatility depending on the bone size and the required strength of fixation.2.7mm screws are typically used for more delicate or thin bones.3.5mm screws provide stronger fixation for larger or more robust fractures.The use of locking screws ensures rigid fixation, preventing any movement at the fracture site and promoting optimal bone healing.4. Left/Right-Sided Plate:The plate comes in left and right versions, pre-contoured to fit the natural anatomy of the left or right distal fibula, minimizing the need for intraoperative adjustments.Pre-contouring ensures a more precise fit, reducing surgical time and enhancing stability post-surgery.5. Material: SS316L (Stainless Steel 316L):SS316L is a high-quality, medical-grade stainless steel known for:Corrosion resistance: Ensures long-term durability and prevents degradation in the body.Mechanical strength: Can withstand the stresses placed on the fibula during rehabilitation.Biocompatibility: Safe for implantation in the human body without causing adverse reactions.6. Anatomical Fit:The plate is pre-contoured to match the natural curvature of the lateral fibula, ensuring a proper anatomical fit and reducing the need for modifications during surgery.The shape and holes are designed to facilitate optimal screw placement and effective stabilization of the fracture.Applications:Fractures of the Distal Fibula:Lateral malleolar fractures.Fractures near the syndesmosis joint between the tibia and fibula.Comminuted fractures or fractures extending into the ankle joint.Osteoporotic Bone: Ideal for use in patients with weakened bone density, where traditional fixation methods may not offer sufficient stability.Deformity Correction: For cases requiring alignment correction in the distal fibula.Post-Traumatic Deformities: Used for reconstructing the fibula after trauma, ensuring proper alignment and function.Key Features:Locking Mechanism: Provides angular stability, ensuring the fracture site remains rigid during healing, even in low-quality bone.Combination Holes: The plate includes a mix of locking and non-locking holes, providing flexibility in fixation.
Locking Distal Lateral Fibula Plate 2.7/3.5mm Left SS316L
589.003 3 Holes
589.004 4 Holes
589.005 5 Holes
589.006 6 Holes
589.007 7 Holes
589.008 8 Holes
589.009 9 Holes

Locking Distal Tibia Medial Plate with Tab 3.5mm Right/Left SS 316L

Request Callback

₹ 1000 / Piece Get Latest Price

Product Brochure
MaterialStainless Steel
Sterile/ Non SterileNon Sterile
Disposable/ ReusableDisposable
BrandJINDAL MEDI SURGE
Model Name/Number593.004
ColorSilver
Packaging TypePack
Usage/ApplicationHospital
Country of OriginMade in India
The Orthopedic Locking Distal Tibia Medial Plate with Tab 3.5mm Right/Left SS316L is a specialized implant designed for the fixation of fractures in the medial aspect of the distal tibia, which is located near the ankle joint. This plate is particularly useful in cases of complex fractures or fractures involving the distal tibia, especially when alignment and stability are critical to ensure proper healing and restore joint function. Here is a detailed breakdown of the features, benefits, and applications of this plate:
1. Locking Plate Design:The locking mechanism involves screws that lock into the plate, providing a fixed-angle construct. This provides superior stability, preventing screw loosening or migration, particularly in osteoporotic or comminuted fractures.The locking system is essential for providing high angular stability in areas where bone quality may not be ideal.2. Medial Distal Tibia Plate:This plate is specifically designed for fractures located on the medial side of the distal tibia, which is crucial for maintaining the structural integrity of the lower leg and ankle.The plate is designed to fit along the medial aspect of the tibia, which is often the site of fractures involving the medial malleolus or fractures that extend into the ankle joint.The plate is contoured to match the natural anatomy of the tibia, ensuring a better fit with minimal need for intraoperative adjustments.3. Tab Feature:The tab on the plate helps with optimal placement and provides additional stabilization in cases of more complex fractures or where the fracture site needs extra support.This tab feature can be especially useful for enhancing the alignment of the bone during fixation, providing more support and helping to prevent rotational or angular deformities during the healing process.4. 3.5mm Screw Compatibility:The plate is compatible with 3.5mm locking screws, which are commonly used for stabilizing fractures in the distal tibia. These screws provide high strength and stability, essential for ensuring secure fixation, particularly in cases of fractures involving multiple bone fragments.3.5mm screws are robust enough to provide adequate fixation for fractures in the distal tibia, but small enough to avoid excessive soft tissue disruption.5. Left/Right-Sided Plate:Available in left and right versions, ensuring that the plate matches the natural anatomy of the tibia and provides optimal fit and fixation for either leg.The pre-contoured design reduces the need for intraoperative modifications, allowing for more precise and efficient surgery.6. Material: SS316L (Stainless Steel 316L):Made from SS316L, a high-grade stainless steel alloy, this plate offers:Corrosion resistance, ensuring long-term durability and preventing degradation within the body.High mechanical strength, capable of withstanding the forces exerted on the tibia during rehabilitation.Biocompatibility, meaning the plate is safe for use in the human body without causing adverse reactions.7. Anatomical Fit:The pre-contoured design of the plate follows the natural anatomy of the medial tibia, allowing for a precise fit and reducing the need for significant intraoperative adjustments.The tab provides additional support for fractures in the medial malleolus or those involving the ankle joint.Applications:Fractures of the Medial Distal Tibia:The plate is ideal for fractures involving the medial malleolus or fractures extending into the ankle joint.
Locking Distal Tibia Medial Plate with Tab 3.5mm Right SS316L
593.004 4 Holes
593.005 6 Holes
593.006 8 Holes
593.007 10 Holes
593.008 12 Holes
593.009 14 Holes
593.010 15 Holes

Locking Posterior Medial Tibia Plate 3.5mm SS 316L

Request Callback

₹ 937 / Piece Get Latest Price

Product Brochure
MaterialStainless Steel
Sterile/ Non SterileNon Sterile
Disposable/ ReusableDisposable
BrandJINDAL MEDI SURGE
Model Name/Number587.002
ColorSilver
Packaging TypePack
Usage/ApplicationHospital
Country of OriginMade in India
The Orthopedic Locking Posterior Medial Tibia Plate 3.5mm SS316L is a specialized implant designed for the fixation of fractures located on the posterior medial aspect of the proximal tibia, especially in complex fractures or those involving the posterior tibial surface. This plate provides stable fixation, minimizes soft tissue irritation, and supports healing in cases where conventional plates may not provide sufficient stability. Here's a detailed breakdown of its features and applications:
1. Locking Plate Design:The locking plate system uses locking screws, which lock into the plate, providing a fixed-angle construct. This ensures high stability, especially in osteoporotic or comminuted fractures.Locking screws prevent micromotion at the fracture site, enhancing healing and reducing the risk of nonunion or malunion.2. Posterior Medial Tibia Plate:The plate is designed specifically for fractures on the posterior medial side of the proximal tibia.Often used for fractures that extend near or into the posterior tibial surface, which is crucial for knee joint function and alignment.Ideal for posterior tibial fractures or those involving posterior ligamentous structures, such as the posterior cruciate ligament (PCL).3. 3.5mm Screw Compatibility:Compatible with 3.5mm locking screws and cortical screws.3.5mm screws provide optimal strength and precision for stabilizing fractures, especially in the proximal tibia.Screws are strategically placed to ensure stable fixation without disrupting the surrounding soft tissues.4. Material: SS316L (Stainless Steel 316L):Made from 316L stainless steel, a high-grade alloy used for medical implants.Key characteristics:Corrosion resistance: Essential for long-term use in the body.High mechanical strength: Can withstand the forces exerted during rehabilitation.Biocompatibility: Safe for implantation, reducing the risk of adverse reactions.5. Anatomic Fit:Pre-contoured to match the natural posterior medial curvature of the tibia, ensuring an accurate fit with minimal adjustments during surgery.Posterior positioning allows the plate to offer optimal support while avoiding interference with major ligaments, tendons, or other anatomical structures in the region.6. Surgical Considerations:Fracture Reduction: Accurate alignment is critical to ensure that the tibia maintains proper alignment with the knee joint and ankle, especially in fractures near the posterior tibial plateau.Plate Placement: The plate is applied to the posterior medial aspect, minimizing soft tissue disruption. This placement is particularly important for fractures near the knee joint or those that involve the posterior tibial surface.Soft Tissue Management: Careful handling of surrounding tissues, such as the posterior cruciate ligament (PCL) and tendons, is necessary to avoid complications.Applications:Posterior Medial Tibial Fractures:Fractures involving the posterior tibial plateau or extending into the joint surface.Comminuted fractures that require rigid fixation and stability for healing.Fractures with Ligament Involvement: Especially useful for fractures near or involving the posterior cruciate ligament (PCL), providing support while preserving ligament function.Post-traumatic Deformities: Correcting deformities or malalignment in the proximal tibia, such as valgus or varus deformities.Osteoporotic Bone: Provides stability for fractures in osteoporotic bone, where traditional plates may not offer sufficient fixation.Key Features:Locking Mechanism: Locking screws provide fixed-angle stability, reducing the risk of screw loosening or migration over time.
Locking Posterior Medial Tibia Plate 3.5mm SS316L
587.002 2 Holes
587.003 4 Holes
587.004 6 Holes
587.005 8 Holes
587.006 10 Holes


LOCKING CLAVICLE HOOK PLATE 3.5MM

Request Callback

₹ 1250 / Piece Get Latest Price

Product Brochure
MaterialTitanium
Size3.5MM
Sterile/ Non SterileNon Sterile
Disposable/ ReusableReusable
BrandJINDAL MEDI SURGE
Model Name/Number531T.003
Usage/ApplicationHospital
Country of OriginMade in India

Minimum order quantity: 1 Piece

LOCKING CLAVICLE HOOK PLATE 3.5MM

Jindal Medi Surge is a CE and ISO Certified leading Manufacturer and Exporter of Surgical and Orthopedic / Orthopaedic Instruments and Devices used for Human (Adult and Pediatric) and Veterinary Surgical Procedures. All Products are made from Surgical Grade Stainless Steel, Aluminum, Titanium & Carbon Fiber Only. Our Products are used by Government Institutes, Private Hospitals, Small Clinics, Individual Doctors Worldwide.

For Bulk Order & Customized Listing, kindly message us.
We sell exclusively on our JMS Brand & also Manufacture on OEM basis for various international brands.

Medial Anterior Clavical Locking Plate Variable Angle Left/Right Titanium

Request Callback

₹ 3812 / Piece Get Latest Price

Product Brochure
Length4 cm
BrandJINDAL MEDI SURGE
Hole Spacing5MM
Suitable ForORTHOPEDIC
Hole Size4 TO 8
Country of OriginMade in India
The Orthopedic Medial Anterior Clavicle Locking Plate Variable Angle Titanium is a specialized implant used to treat fractures in the medial (inner) region of the clavicle, particularly those near the sternoclavicular joint or coracoclavicular ligaments. This plate features a variable angle locking mechanism, allowing for more flexibility in screw placement while maintaining stable fixation, making it particularly useful for complex fractures or challenging anatomy.
Here's a breakdown of the key features, benefits, and surgical considerations for this plate:
1. Medial Anterior Locking Plate Design:The medial anterior clavicle locking plate is designed to provide optimal fixation for fractures in the medial clavicle, often located near the sternoclavicular joint. These fractures are typically more challenging due to their proximity to vital structures like the subclavian vessels and brachial plexus.The pre-contoured plate is designed to match the natural anatomical curvature of the clavicle, reducing the need for intraoperative adjustments and ensuring a precise fit for the fracture site.2. Variable Angle Locking System:The variable angle locking system allows the surgeon to adjust the angle of the locking screws within a specific range, providing more flexibility when fixing the fracture. This is particularly useful when dealing with complex or non-ideal fracture patterns.The ability to adjust the angle of the screws provides a more customized fit for the bone's anatomy and ensures a more stable construct, reducing the risk of malunion or nonunion.Variable angle is especially helpful in cases where the fracture line doesn't align perfectly with the standard holes in the plate, giving surgeons more control over screw positioning.3. Titanium Material:The plate is made from titanium, a biocompatible, lightweight, and corrosion-resistant material, ideal for use in orthopedic implants. Titanium is known for its strength, durability, and ability to integrate with bone over time, reducing the risk of complications like implant rejection or infection.Titanium's flexibility and strength-to-weight ratio make it well-suited for applications like clavicle fracture fixation, where the plate must bear significant loads while minimizing soft tissue irritation.4. Anatomical Fit:The pre-contoured design ensures that the plate fits snugly along the medial clavicle, allowing for optimal alignment of the fracture fragments. This helps restore the natural anatomy of the clavicle, which is essential for proper shoulder function.The low-profile design of the plate helps reduce irritation to surrounding soft tissues and enhances patient comfort post-surgery.5. Applications:Medial Clavicle Fractures:Ideal for fractures occurring in the medial clavicle, especially those near the sternoclavicular joint where fractures are often more challenging and require stable fixation to prevent complications.Proximal Clavicle Fractures:Effective for proximal clavicle fractures, where the plate helps stabilize the fracture and ensures proper alignment of the bone.Comminuted or Displaced Fractures:Suitable for comminuted fractures, where the bone is broken into multiple pieces, or displaced fractures where the fracture ends have moved out of position.Osteoporotic Bone:The locking mechanism provides enhanced stability, making the plate ideal for patients with osteoporotic bones or those with compromised bone quality.

Medial Anterior Clavical Locking Plate Variable Angle Left Titanium
5112LVT.104 4 Holes
5112LVT.105 5 Holes
5112LVT.106 6 Holes
5112LVT.107 7 Holes
5112LVT.108 8 Holes












X

Contact Us

Nitin Jindal (Partner)
Jindal Medi Surge
5a/5, Ansari Road, Darya Ganj, New Delhi - 110002, Delhi, India

Get Directions
Send Email
Share: